Product Catalog

Conductive Soft Rubber Wheels (XY/XZ Lines) — Static-Control Comfort Ride for Electronics and Film Handling

Third-party brand — supplied via our sourcing network

Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term.

Updated 2026-11

Conductive soft rubber wheels are the static-control branch of the X-tra soft rubber family: the same high-deflection comfort ride, compounded with carbon so the wheel bleeds static charge to ground through the hub and axle instead of letting it build on the cart. The manufacturer selection chart publishes two lines — XY, a flat-tread wheel at 200-675 lb over 3-8 in diameters, and XZ, a round-tread variant at 450-500 lb over 6-8 in — both rated -45 to +180 °F with the family’s High floor protection and Good rollability.

Third-party brand — supplied via our sourcing network. Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term.

Specifications

Type Conductive X-tra soft rubber wheels (carbon-compounded soft rubber); XY flat tread, XZ round tread; plain bore or with bearings
XY line (manufacturer reference) 200-675 lb at 3-8 in diameter, flat tread; floor protection High, rollability Good, chemical resistance Good; -45 to +180 °F
XZ line (manufacturer reference) 450-500 lb at 6-8 in diameter, round tread; floor protection High, rollability Good, chemical resistance Good; -45 to +180 °F
Family context (manufacturer reference) Non-conductive X-tra soft lines (XS flat, XR round) cover the same comfort-ride class without the static-control compound — the XY/XZ lines are the conductive branch
ESD class context (industry reference) Conductive materials are defined by low electrical resistance and rapid charge bleed to ground — verify the resistance band against your ESD program, not against the wheel name
Third-party brand — supplied via our sourcing network Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term.
Third-party brand — supplied via our sourcing network Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term.
RollMaster commercial coverage 18 months as RollMaster commercial coverage; exact coverage, exclusions and order terms are confirmed in the written quotation. Any manufacturer warranty is separate and must be confirmed for the named manufacturer and exact model.

XY and XZ are separate manufacturer lines — each published band stays its own row and is never merged into one family figure. The resistance value of your wheel at your humidity and wear state is a measurement item; the published chart carries capacity and temperature, not ohms.

Applications & Selection

Where a conductive soft rubber wheel earns its place

Two duties intersect here. The first is comfort: an X-tra soft rubber tread rolls quietly, shields fragile floors, and shrugs off small debris that would telegraph through a harder wheel into a precision instrument or a stacked film roll. The second is static: where carts collect charge by rolling across insulating floors — electronics assembly, photographic film, powder handling, solvent-adjacent areas — a conductive wheel continuously drains that charge instead of releasing it in a spark at the next touch point. Published class guidance defines conductive material by very low electrical resistance and rapid conduction to ground, which is why the wheel must be verified with an ohmmeter in service, not assumed from its color or name.

The boundary is equally practical: XY and XZ carry 200-675 lb and 450-500 lb respectively — comfort-ride loads, not tow-line loads. They are floor wheels; on angle-iron track or in high-heat zones the conductive requirement needs a different construction entirely. And a conductive wheel under a non-conductive cart (plastic deck, isolated swivel bearings) drains nothing — the whole path from deck to floor decides.

Selection points to settle before you RFQ

State the ESD requirement as a resistance band and a verification method, not as the word "conductive": your program’s band (conductive versus static-dissipative) may or may not match the wheel’s as-shipped resistance, and wear changes it over time. Then size normally: load per wheel with your safety divisor, diameter, tread type (XY flat for straight-line stability, XZ round for tracking and turning), bore and bearing, floor surface, and chemical exposure — the published lines are chemical-resistant Good and -45 to +180 °F, which covers cold rooms and wash-adjacent areas but not ovens.

Third-party brand — supplied via our sourcing network. Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term.

How a buyer verifies the resistance claim — and what this page cannot verify

Verify the class against a named standard, not against the adjective on the box. The referenced data-hall wheel guidance is exact about the numbers: ANSI/ESD S20.20-2021 defines two wheel bands by surface resistance — conductive at or below 1 × 10^6 Ω, dissipative above 1 × 10^6 and below 1 × 10^9 Ω — and ANSI/ESD STM7.1 is the test method that measures this resistance. Compliance references in the trade run to ANSI/ESD S20.20 or IEC 61340. That gives a buyer a verifiable number instead of a word: state your band in the RFQ, require as-shipped readings taken per the named test method, and do not accept "conductive" as a spec until a meter has said so — a band claim with no test method behind it is not verifiable against anything. And the ESD Association itself refuses the shortcut in the other direction: a material’s low charging properties are not necessarily predicted by its resistance or resistivity — a low ohm reading alone does not prove the wheel charges less in service. Treat the band as necessary, never as sufficient.

The reading is a moving number, and the published maintenance guidance says why: accumulated dirt, oils, or floor coatings can insulate the wheel’s contact surface, increasing electrical resistance and reducing static dissipation effectiveness, and worn treads may lose conductivity as the conductive surface layer is abraded. The same guidance names the instrument and the cadence — regular resistance testing using a megohmmeter or specialized ESD tester can verify that the wheels continue to meet specified resistance ranges — and the trade’s maintenance rule agrees: ESD casters should be regularly tested, because wear and tear, dirt and other factors can reduce their effectiveness over time. A wheel that measured comfortably inside band at delivery does not promise the same reading after a quarter of that duty; the re-check is part of the spec. Do not let a passing commissioning test retire the item: beyond the first measurement, cleanliness and tread depth own the reading, and a wheel does not fail loudly — it fails quietly, at a resistance number nobody measured.

Boundaries this page cannot cross for you: we cannot verify your floor, your grounding path, or the resistance of a delivered batch unless the measurement is made and recorded — as-shipped readings are taken and documented only when you ask with the RFQ. The system-level rule is not ours to waive: the wheel must be part of a grounded path that includes the floor and the equipment frame, and ESD casters must be used with ESD-protective flooring to be effective. Never merge the two S20.20 bands into one promise — a dissipative wheel does not fail a program that asked for dissipative; it fails only when the program demanded the conductive band. And what no catalog page can verify: the ohms of the batch you receive, the ohms after 90 days of your floor chemistry, and whether your deck-to-floor path stays inside band — only measurements on your assembled cart, repeated in service, can. If your site runs an auxiliary ground — a water pipe, building frame or ground stake — it must be bonded to the equipment grounding conductor; an unbonded second ground preserves a difference in potential, which is exactly the hazard the grounding path exists to remove. And in highly sensitive environments, additional ESD controls such as grounding cables or straps may be necessary — the wheel never exempts the rest of the path.

Quality & Verification

The spec values for Conductive Soft Rubber Wheels draw on 10 field-level source records — 1 tenant confirmed, 3 manufacturer reference, 6 industry reference.

Claim on this pageHow a buyer verifies it
Load rating Catalog ratings bind one configuration. State wheel, bearing, speed and duty. Require that exact rating on the quotation.
Sample or test report Request test data or certificates per SKU. Agree acceptance in writing before the order.
Materials and tread Confirm material by certificate, not description. Unresolved options are fixed at quotation.
Bearings Name the bearing type in the RFQ. "Standard bearing" is not a specification.
Standards and compliance Name the standard and certify against it. An unnamed equivalent is not a certification.

What this page cannot verify

  • No figure on this page is our own lab result.
  • The binding rating is the quotation figure.
  • supplier conductive soft rubber line ratings — no owner per-configuration data — rendered confirm-at-quotation; requisitioned, not speculatively filled

Sources for this page

  1. [1] XY line 200-675 lb / 3-8 in / High / Good / Good / -45 to +180 F — manufacturer reference (https://albioncasters.com/caster-college/wheel-selection-chart) — manufacturer wheel-selection chart row XY (publisher typo "Condutive" in source)
  2. [2] XZ line 450-500 lb / 6-8 in / -45 to +180 F — manufacturer reference (https://albioncasters.com/caster-college/wheel-selection-chart) — manufacturer chart row XZ
  3. [3] XS/XR non-conductive adjacent rows — manufacturer reference (https://albioncasters.com/caster-college/wheel-selection-chart) — family context only
  4. [4] conductive material definition (low resistance, rapid bleed to ground) — industry reference (https://www.palmetto-industries.com/static-dissipative-vs-conductive-what-is-the-difference/) — second-publisher class reference
  5. [5] ESD verification (ANSI/ESD S20.20-2021 bands: conductive ≤ 1e6 Ω, dissipative 1e6–1e9 Ω; ANSI/ESD STM7.1 test method; system-level grounded path incl. floor and equipment frame) — industry reference (https://casterhq.com/collections/data-center-casters-for-server-rack-mobility) — data-hall wheel ESD bands and test-method reference
  6. [6] resistance drift (dirt/oils/floor coatings insulate contact surface and raise resistance; megohmmeter or ESD tester verification; worn treads lose conductivity as surface layer abraded; mild-detergent cleaning) — industry reference (https://zhxpreci.com/product-series/industrial-rubber-wheels/custom-anti-static-industrial-rubber-wheels/) — anti-static rubber wheel maintenance guidance
  7. [7] ESD practice (must be used with ESD-protective flooring; regular testing; wear/dirt reduce effectiveness over time; ANSI/ESD S20.20 or IEC 61340 compliance) — industry reference (https://bullcaster.com/casters-faq) — ESD caster FAQ, practice items 4-6
  8. [8] measurement standards + low-charging boundary (STM11.11/11.12 test methods; low charging properties not necessarily predicted by resistance) — industry reference (https://www.esda.org/esd-overview/esd-fundamentals/part-3-basic-esd-control-procedures-and-materials/) — ESD Association fundamentals, materials section
  9. [9] auxiliary ground bonding rule (water pipe / building frame / ground stake must be bonded to equipment grounding conductor) — industry reference (https://www.esda.org/esd-overview/esd-fundamentals/part-3-basic-esd-control-procedures-and-materials/) — same publisher as measurement reference — grounding section
  10. [10] lead_time/moq/warranty — tenant confirmed (first-party) — owner answers 2026-10-26 (established supplier figures, prior batches)

Frequently Asked Questions

What resistance should a conductive soft rubber wheel actually measure?

Quote the standard, not the adjective. ANSI/ESD S20.20-2021 defines two wheel bands by surface resistance — conductive at or below 1 × 10^6 Ω, dissipative above 1 × 10^6 and below 1 × 10^9 Ω — and ANSI/ESD STM7.1 is the referenced test method for this resistance. Match the band to your ESD program (EOS-critical processes usually demand the conductive band; general static control usually lives in the dissipative band) and require as-shipped readings per the named method with the shipment. If a supplier cannot name the test method behind its "conductive" claim, the claim is not yet a spec. And remember the standard’s own boundary: a material’s low charging properties are not necessarily predicted by its resistance or resistivity — so unless your ESD program accepts the wheel class explicitly, no single ohm number closes the question.

Our wheels passed the resistance check at delivery — why do they drift out of band later?

Because the reading rides on the tread surface. Published maintenance guidance: accumulated dirt, oils, or floor coatings can insulate the wheel’s contact surface and increase electrical resistance, and worn treads may lose conductivity as the conductive surface layer is abraded. Regular resistance testing with a megohmmeter or a specialized ESD tester verifies that wheels continue to meet the specified ranges; cleaning with mild detergent and water helps maintain the conductive pathways; and wheels whose tread depth is significantly reduced should be replaced, not trusted. Schedule the re-check into the ESD program — a wheel is not permanently conductive because it passed once. The failure never announces itself: nothing deforms visibly when conductivity dies — only when someone measures the surface again does the drift show.

Conductive soft rubber wheels or ESD polyurethane wheels — which do I need?

They solve the same problem with different ride qualities. The conductive soft rubber lines (XY/XZ) give you floor protection and quiet rolling at light loads (200-675 lb); ESD polyurethane carries more load and resists flat-spotting under heavy static duty but is harder on fragile floors. If your route crosses finished floors or carries delicate instruments, soft rubber wins; if it carries 1,000 lb carts at speed, polyurethane does. Our ESD wheels page covers the resistance-band specification both must meet.

Does a conductive wheel alone make my cart ESD-safe?

No. The wheel is one segment of the grounding path: cart deck, casters, bearings and floor all sit in series with it. A conductive wheel under a plastic-sleeved stem or on a highly insulating floor drains nothing. Specify the resistance band end-to-end, verify it with measurements at the assembled cart, and re-verify as treads wear — the knowledge guides below give the band values and the verification method.

What is the difference between the XY and XZ lines?

Tread geometry and size. XY is a flat-tread wheel, published at 200-675 lb over 3-8 in diameters — the general choice for straight runs and maximum footprint. XZ is a round-tread wheel at 450-500 lb over 6-8 in — the round profile tracks and turns more easily, at the cost of a smaller contact patch. Both share the same -45 to +180 °F band and the same conductive compound.

Ordering & Documentation

Documents

Every order ships with a packing list and commercial invoice. Dimensional drawings (diameter, tread width, bore, hub length) are available on request; if your ESD program needs as-shipped resistance readings, ask with the RFQ so the measurement is made and recorded before shipment.

Quotation

A quotation needs: load per wheel with your safety divisor, diameter and tread type (XY flat or XZ round), bore and bearings, floor surface, temperature and chemical exposure, your ESD resistance band with the verification method, and quantity. The confirmed quotation states the rating for your configuration; the chart bands above are published line references, not the commitment.

Sample & supply

Third-party brand — supplied via our sourcing network. Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term.