The buyer decision
Do not select C3 simply because a caster will operate in a freezer, and do not treat a C3 suffix as proof that the mounted wheel bearing will retain adequate operating clearance. Distinguish the bearing's unmounted initial clearance, its mounted clearance after shaft/hub fits, and its operating clearance after temperature and other effects. A replacement with the same bearing envelope or a larger initial-clearance suffix may still behave differently once installed in a particular wheel centre.
What the independent bearing makers establish
SKF — Rolling bearings, PUB BU/P1 17000/1 EN, October 2018, printed pp.182–185, §B.7. SKF defines initial, mounted and operating clearance separately. It explains that interference fits expand the inner ring or compress the outer ring, reducing initial clearance. Its fit reduction is expressed as Δrfit = Δ1f1 + Δ2f2. For the temperature contribution, SKF gives Δrtemp = 0.012 ΔT dm, where ΔT is the inner-to-outer-ring temperature difference and dm = (d + D)/2 is the bearing mean diameter. The stated model is for a steel shaft and a steel or cast-iron housing. SKF also says start-up temperature gradients are transient, that the smallest-thermal-capacity component heats faster, and that light-alloy components can make temperature effects more pronounced.
NSK — Handling Instructions for Bearings, printed pp.7–10, §2.1 “Fits and Clearances”, Tables 1–3 and Eq. (3); publication date not stated in the consulted PDF. NSK states that 70–90% of effective interference can appear as a reduction in radial clearance. It describes a usual 5–10°C operating difference between inner and outer rings, but says this can be greater when the inner ring is heated or the outer ring cooled. Its temperature equation is δt = α × Δt × De, with bearing-steel α = 12.5 × 10−6 per °C; for ball bearings De = 1/5 × (4D + d). NSK notes that C3 or C4 clearance may be required depending on fit and temperature conditions. Its fit tables are explicitly bounded to solid steel shafts and cast-iron/steel housings; the document separately calls for tighter interference with light-alloy housings.
Why the two calculation approaches are not a universal caster formula
| Source approach | Original basis | Boundary for a caster buyer |
|---|---|---|
| SKF temperature reduction | Δrtemp = 0.012 ΔT dm; dm = (d + D)/2; steel shaft and steel/cast-iron housing | Do not apply unchanged to a nylon or polyurethane wheel centre, or to an unknown hub fit. |
| NSK temperature reduction | δt = α Δt De; α = 12.5 × 10−6/°C; ball-bearing De = (4D + d)/5 | Its raceway-diameter term and bearing-steel assumption are not the same model input as SKF's mean-diameter expression. |
| NSK fit reduction | 70–90% of effective interference appears as radial-clearance reduction | The actual interference depends on measured axle and housing-seat dimensions, tolerances, surface condition and material; a nominal bore alone is insufficient. |
The formulas should be read as each manufacturer's calculation method under its stated assumptions, not averaged into a third formula. The difference in characteristic diameter is a real modelling distinction; neither source provides a validated wheel-hub calculation for every caster construction.
The hidden cold-transition condition
The relevant thermal input in both sources is the temperature difference across the bearing, not simply the room's advertised minimum temperature. A cold-soaked bearing that is close to thermal equilibrium is a different state from a warm inner ring/axle exposed to a rapidly cooled outer ring or hub. SKF explicitly distinguishes start-up transients from steady state; NSK specifically notes that cooling the outer ring can increase the ring-to-ring difference. A hot wash followed by rapid entry into a cold room is therefore a condition to describe and verify, not a clearance reduction that can be calculated from ambient temperature alone.
Wheel-centre material matters too. The sources provide steel, cast-iron and light-alloy guidance, but no validated thermal-fit model for a polymer hub. Since caster wheels may use nylon, polyurethane, cast iron or other wheel centres, the bearing maker's steel/metal housing equation cannot be silently transferred to an unspecified wheel hub. The exact hub material, seat dimensions and assembly method must be known before any clearance calculation is trusted.
What to request before approving a substitution
- Full bearing manufacturer and designation, including clearance suffix, seal/shield suffix and bearing type.
- Wheel-centre material and construction; actual bearing-seat bore and axle diameters, tolerances, roundness and surface condition.
- Whether the outer ring is press-fitted, bonded, loosely retained or clamped; include axle, spacer, washer and nut stack and the assembly/tightening method.
- Thermal sequence: minimum ambient temperature, cold-soak duration, wash-water temperature, cooling rate, delay before freezer entry, and whether the wheel is stationary under load or rotating.
- The supplier's mounted-clearance or operating-clearance basis, including the exact fit and temperature assumptions. If unavailable, agree an assembly-level rotation/torque check after the representative thermal sequence.
- Separate confirmation for the wheel bearing and swivel-head bearing; the clearance suffix in one does not qualify the other.
Practical rejection rule: if the supplier can provide only “C3” or a wheel temperature range but cannot identify the hub material, actual fits and mounted-clearance basis, record cold-transition clearance suitability as not demonstrated. This is not proof that the wheel will seize or fail; it is a statement that the available evidence does not qualify the substitution.
Evidence boundary
SKF's temperature equation is limited to its stated steel-shaft/steel-or-cast-iron-housing model. NSK's fit tables and thermal equation do not establish a polymer-hub fit calculation. Neither source gives a universal C3 selection rule for caster wheels, a generic cold-temperature clearance allowance or a complete-caster torque threshold. No bearing-seat dimensions, mounted-clearance measurements, thermal-cycle results or cold-start tests are available for products supplied by this business. This guide identifies the information required for a defensible supplier decision; it does not claim that C3, CN or any particular bearing is suitable or unsuitable for a specific caster.
Sources: SKF, Rolling bearings, PUB BU/P1 17000/1 EN (October 2018), printed pp.182–185, §B.7 “Selecting internal clearance or preload”, including “Clearance reduction caused by interference fits”, “Clearance reduction caused by temperature difference between shaft, bearing rings and housing” and “Required minimum initial internal clearance”, https://www.skf.com/binaries/pub12/Images/0901d196802809de-Rolling-bearings---17000_1-EN_tcm_12-121486.pdf. NSK, Handling Instructions for Bearings, publication date not stated in the consulted PDF, printed pp.7–10, §2.1 “Fits and Clearances”, Tables 1–3 and Eq. (3), https://www.nsk.com/content/dam/nsk-marketing/projects-completed/literature/service/handling-instructions/bearings_handling-instructions/en_bearings_handling-instructions/preview-pdf_bearings_handling-instructions_en/EN_Handling_Instructions_for_Bearings_HIB_Service-Brochure_low-res.pdf.