Decision first
Do not treat a matching top-plate footprint and bolt pattern as proof of a safe drop-in installation. Geometric fit is one gate. Attachment qualification is another: use the mounting method and fixing points specified for the exact caster, obtain its approved hardware and torque instruction, and confirm that the equipment-side support is suitable for the actual duty.
What the manufacturer instructions reveal
YUEI's Caster Catalog Vol.18 says plate-type casters are installed with bolts and nuts and instructs the user to use all mounting holes. Its separate mounting warnings state that insufficiently secured screw-in, insertion and angle fittings may reduce load capacity. On printed p.10 it says mounting bolts must be tightened to prevent loosening and calls for the correct torque on screw-in types. The catalogue treats these mounting systems as distinct connections, not as variations of one universal fixing recipe.
Bosch Rexroth's Assembly Technology Catalog gives a concrete but tightly bounded example: on p.2, drawing 00109723 shows an M12 interface, M12×40 ISO 4762 bolt, washer and 35 Nm tightening torque for the illustrated bolt-mounted caster assembly. The same page also depicts a profile-slot mounting alternative. The 35 Nm figure belongs only to that Bosch Rexroth arrangement; it is not a generic caster torque and must not be copied to a different bolt, product or frame.
TENTE's plate-fitting guidance says the required plate-hole diameter depends on the selected castor and fixing hardware. It also says the fixing must pass correctly and create a stable connection to the equipment structure for safe load transfer. This means the plate drawing and the equipment-side connection must be checked together.
The equipment frame is part of the installation
ICWM's “Frame and Fasteners” maintenance guidance asks users to tighten loose bolts and nuts, inspect broken welds and frame distortion, ensure mounting bolts are secured, and use lock nuts or lock washers when mounting casters. The frame and its fasteners are therefore not invisible details outside the buyer's acceptance process.
This does not create a universal structural formula. The cited sources do not specify one bolt grade, torque, thread-engagement length, frame thickness or backing-plate size for every caster. A product-specific instruction must remain product-specific, and an unknown or modified equipment frame may require review by the equipment's responsible designer.
Two-stage replacement decision
- Stage 1 — geometric fit: compare plate footprint, hole centres, hole diameter/slot geometry, installed height and surrounding clearance
- Stage 2 — attachment qualification: identify through-bolted plate, tapped/threaded connection, profile slot, insertion stem or angle bracket; confirm all intended fixing points, approved fasteners, washers/nuts, locking method and the exact product's tightening instruction
- Equipment-side check: provide the mounting drawing and frame material/section details; check for local support, distortion, damaged welds, loose fasteners and access to install/inspect the fixing
- Do not transfer torque: Bosch Rexroth's 35 Nm example applies only to drawing 00109723 and its stated M12×40/washer arrangement
What to put in the RFQ
Send the equipment mounting drawing, material and section details, caster plate drawing, hole diameter and centre spacing, mounting method, backside access, existing fastener specification and any known torque instruction. Ask the supplier to identify the exact approved fixing hardware and installation instruction for the quoted caster. If the frame joint is unknown or being modified, have the equipment-side connection reviewed separately; do not ask the caster's catalogue rating to qualify an arbitrary mounting joint.
What the evidence does not prove
- YUEI's all-holes instruction and mounting warnings apply to the mounting arrangements in its Vol.18 catalogue
- Bosch Rexroth's M12×40 and 35 Nm values apply only to the illustrated assembly, drawing 00109723
- ICWM's lock-nut/lock-washer advice is maintenance guidance, not a structural design equation
- TENTE does not publish a universal bolt grade, torque or equipment-frame thickness in the cited FAQ
- No universal mounting-joint capacity, bolt torque, thread engagement or edge-distance rule can be derived from these sources
- No mounting-joint or fastener test was performed on products supplied by this business
Sources
- YUEI, Caster Catalog Vol.18, 2022, printed pp.9–10, “Types of mounting methods” and “Precautions for mounting a caster”. Original catalogue
- Bosch Rexroth AG, Assembly Technology Catalog, PDF version 2023-09-263, p.2, drawing 00109723, M12×40 ISO 4762 / washer / 35 Nm bolt-mounted assembly. Catalogue PDF
- Institute of Caster and Wheel Manufacturers (ICWM), “Maintenance Tips”, current guidance page, accessed 2026-11-25, “Frame and Fasteners”. ICWM guidance
- TENTE, “Secure Mounting with Plate Fitting Castors”, current manufacturer page, accessed 2026-11-25, FAQs on hole diameter, plate size and hole centres. Manufacturer guidance