Buyer decision guide · 2026-11-25

Does a hot caster wheel keep its room-temperature load rating?

No—not unless the exact wheel series has a load-at-temperature rating or manufacturer-approved correction for the actual duty. Temperature range and load capacity are separate specifications. Published correction methods differ by manufacturer and product family, so a universal “phenolic”, “urethane” or “nylon” derating factor is not supported.

The buyer decision

If a caster enters a heated process, do not carry its room-temperature catalogue load into the hot zone by default. Ask for the exact model's load at the actual wheel temperature, and check whether the quoted value applies to continuous or intermittent exposure, time spent hot, rolling or stationary duty, and the complete caster assembly.

Three independent manufacturers, three different evidence formats

Source and locationPublished evidenceComparison boundary
Ganter Norm, Wheels and Casters — Operating Conditions, §3.10, “Temperature Correction Factors”At +60 to +80°C, GN 22872/22873 are 0.5; GN 22874/22875 are 0.6; GN 22882 is 0.7; GN 22885–22887 are 0.8; GN 22894 is 1.0. A factor of 1 is 100% of the standard-sheet load capacity.Factors are tied to Ganter's individual GN codes, not generic material classes. A dash means no factor is published for that series/range.
Acorn Industrial Products, Wheel Selection Criteria, printed p.20Acorn plots temperature factors for Vulkollan, polyamide, rubber, urethane and cast iron. Its own method calculates adjusted wheel capacity as T% × V% × E% × normal load, separating temperature, speed and operating environment.The curves are graphical guidance, not exact SKU ratings; the formula is Acorn's method, not a universal industry equation.
Fallshaw Wheels & Castors, “High and low temperature castors”, “Phenolic”Fallshaw states phenolic wheel capacity decreases from 125 kg at 100°C to 40 kg at 300°C. Arithmetic from those figures gives 32% retained capacity, or a 68% decrease.The page does not identify exact SKU, test method, exposure duration or full configuration. The calculated 68% is not transferable to other phenolic wheels.

What the cross-source comparison establishes

All three sources treat temperature as relevant to usable load, but their numbers are not directly comparable. Ganter reports correction factors by its own product code. Acorn reports material-family curves and a multi-factor method. Fallshaw reports two load values for a phenolic wheel without a full test protocol. The evidence does not share a common wheel diameter, compound, core, bearing, applied-load arrangement, temperature dwell or test method.

Ganter's own +60 to +80°C table spans 0.5 to 1.0 across listed series. That spread is enough to reject a single temperature multiplier for all wheels. It does not prove which material is superior: the series may differ in construction and the table is not a controlled cross-material experiment.

Acorn's separate T%, V% and E% factors show why temperature should not be considered in isolation: speed and operating severity also affect its selection calculation. Do not apply Acorn's factors to another supplier's normal rating unless that supplier explicitly adopts the same method.

Fallshaw's 125 kg at 100°C and 40 kg at 300°C provide a warning that a high-temperature wheel can have a substantially different load limit at temperature. The 68% reduction is calculated only from those two Fallshaw figures; it is not a measured continuous derating curve and cannot size another wheel.

When the rating is not yet qualified

If a supplier gives only a maximum temperature, generic material range or room-temperature load value, the load capacity at the hot operating point remains unverified. Do not infer full catalogue capacity, interpolate between unrelated product series, or assume a temperature factor based only on a material name.

What to specify in the RFQ

  • Exact wheel/caster model, wheel compound and core construction; identify whether the rating is for the wheel alone or complete caster
  • Room-temperature reference load and exact temperature at the wheel, not only oven/room ambient
  • Continuous, intermittent or peak exposure; dwell time at temperature; cooling time and thermal-cycle frequency
  • Whether the wheel is stationary under load in the hot zone or rolling through it; speed, duty cycle, floor and obstacle severity
  • Model-specific load-versus-temperature table or written load correction, including the reference test method
  • Separate temperature limits for bearing, axle, hub, lubricant, seals and bracket
  • Test report or manufacturer confirmation for the exact quoted configuration and acceptance criteria

Scope and limits

Ganter's coefficients apply to the listed GN series. Acorn's curves are graphical guidance and were not converted into exact numeric points. Fallshaw's phenolic load example lacks SKU and test details needed to reconstruct its protocol. No common cross-brand test, universal correction factor or complete temperature-load curve was found. No high-temperature load test has been performed on products supplied by this business, and no high-temperature load guarantee is made.

Sources: Ganter Norm, Wheels and Casters — Operating Conditions, current online guide accessed 2026-11-25, §3.10 “Temperature Correction Factors”, https://live-katalog.ganternorm.com/pdf/ganter/en/Raeder%20und%20Rollen_Einsatzbedingungen.pdf?dispositiontype=attachment. Acorn Industrial Products Co., Wheel Selection Criteria, “00 Wheel Selection Correction Criteria”, printed p.20, https://www.acornindprod.com/pdfs/caster-categories/00%20Wheel%20Selection%20Criteria.pdf. Fallshaw Wheels & Castors, “High and low temperature castors”, current manufacturer page accessed 2026-11-25, “High temperature use” and “Wheel types — Phenolic”, https://www.fallshaw.com.au/information/about-high-and-low-temperature-castors.