Buyer decision guide · 2026-11-25

A castor-chair pass does not qualify an industrial cart or a newly installed floor

Do not treat a resilient floor's castor-chair test as approval for heavy industrial rolling traffic. Test method, floor installation age, adhesive/substrate condition and actual route are separate conditions. A caster's load rating or larger wheel diameter cannot bridge those evidence gaps.

The buyer decision: three separate qualification gates

  1. Permanent floor-system capability: the exact floor covering, adhesive, substrate preparation, joints and floor condition must tolerate the intended static and dynamic loads.
  2. Installation-phase release: the flooring manufacturer may prohibit rolling loads while adhesive is setting or drying, even if the finished product passed a castor-chair test.
  3. Route and caster duty: actual wheel reactions, joint/threshold geometry, speed, turns, repetitions and parking dwell must be addressed. A larger wheel may negotiate irregularities more easily, but does not certify the floor assembly.

These gates answer different questions. Passing one does not establish the others. A test result is meaningful only for its named specimen, method, load, wheel configuration and acceptance criterion.

What the floor test does — and does not — establish

ISO 4918:2026, Edition 3 (published 20 November 2026), specifies methods for assessing appearance/stability changes in textile flooring and damage to resilient, laminate or modular mechanically locked floor coverings under movement of a swivel castor chair. Its abstract includes layer detachment, opening of joints, cracks and crazing. It does not describe an industrial cart or pallet-truck qualification.

SGS-CSTC report SHIN2312002151CM01_EN, dated 2023-12-29, identifies an SPC sample submitted by the customer (4+1 mm IXPE to 5+1 mm IXPE specification). Printed p.11 §7 uses one Φ750 mm × 5 mm specimen, 90 kg load, Type W wheels and 25,000 cycles under ISO 10582:2017 Table 2 / ISO 4918:2016/Amd 1:2018. Result: “No visible damage.” The report states results refer to the tested sample(s).

Interpretation: this supports that one submitted sample showed no visible damage under that specific older-edition chair test. It does not provide a maximum industrial wheel load, static dwell rating, impact/threshold test, industrial route speed, turning-scrub test or approval of another floor installation. It must not be relabelled as an ISO 4918:2026 test or universal SPC-floor guarantee.

Installation age creates a temporary rolling-load boundary

Parterre's Commercial Dry Back Luxury Flooring Installation Instructions (2023-01-12), printed p.12, says no traffic for 24 hours and no rolling-load traffic for at least 72 hours after installation while adhesive sets and dries. Printed p.15 recommends wood panels for heavy objects and warns that wheeled equipment over newly adhered flooring can create permanent wheel tracking. This is the named Parterre installation context.

Armstrong Flooring Commercial independently states in “Performance Criteria FAQs” / “What types of loads affect resilient flooring?” that newly installed floors should not receive routine rolling loads for at least 72 hours. It recommends protective panels of 1/4 inch or thicker plywood, hardboard or equivalent for heavy fixtures/appliances moved on casters. Agreement on 72 hours is not a universal cure-time specification for every adhesive, floor type, temperature or installation. Follow the exact floor and adhesive instructions; obtain written release if traffic must resume sooner.

The substrate and adhesive can be the weak link

XL Brands/Bostik's Technical Bulletin: Vinyl Flooring Indentations (revision 2019-04-10), paragraphs 3–5, describes concrete moisture softening adhesive under sheet vinyl and allowing wheel marks. It also says over-watered floor patch/leveling materials can weaken the substrate and permit indentation under stationary equipment loads. The bulletin's example of a hospital bed with a heavy patient weighing up to 900 lb and thin, sharp-profiled wheels is an example, not a universal 900 lb floor limit.

Armstrong separately distinguishes impact loads from static loads and notes smaller/sharper impact areas can be more damaging; it also warns a wheel's bearing surface is deceptively small. The floor's wear layer alone does not determine the result: adhesive condition, substrate moisture, patch/leveler quality, contact area and load duration matter.

What a larger wheel can solve — and what it cannot

Darcor / Conveyer & Caster's manual-material-handling white paper, §IV.C “Operating Environment” (printed p.19), says rougher or more uneven surfaces call for larger wheel diameters. It specifically lists cracks, seams, expansion joints, grates and door thresholds as irregularities that can stop small wheels, while larger wheels cross them more easily.

This is qualitative wheel-selection guidance, not a universal joint-gap or step-height limit. It does not show that a particular wheel crosses a particular joint at a stated load/speed without impact, floor-edge damage or cargo shock. Nor does it override floor rolling-load limits. A floor can remain vulnerable because of weak adhesive/substrate even when a caster crosses the joint easily.

How to qualify a real industrial route

  1. Identify the installed floor: product/construction (sheet vinyl, dry-back LVT, loose-lay, SPC/rigid core or modular locking), thickness, adhesive, substrate, patch/leveler, moisture status, seams/joints and installation date.
  2. Get floor-side evidence: request the exact castor-chair test edition/report and separate written guidance for industrial rolling loads, static dwell, impact/threshold traffic and warranty conditions. Confirm who approved the adhesive/substrate combination.
  3. Describe the route: record joint/threshold gap and height, edge shape, grates, ramps, turns, speed, pass frequency and loaded parking time. Do not infer a permissible joint size from wheel diameter alone.
  4. Describe the caster: state maximum actual reaction per wheel (including uneven-floor/off-centre loading), wheel diameter, tread width/profile, compound, speed, turning pattern and obstacle geometry. Ask for evidence on representative floor construction.
  5. Separate acceptance outcomes: define permanent indentation, wheel tracking, seam/joint opening, edge damage, scuffing and push/start force independently. “No visible damage” under a chair test is not an all-purpose pass.
  6. Control installation window: follow the exact no-traffic/no-rolling-load period. If rolling traffic cannot be delayed, obtain the floor maker/installer's written protective-panel method and release; do not assume generic plywood thickness applies to every system.

Evidence comparison and comparability limits

SourceWhat it establishesWhat it does not establish
ISO 4918:2026 scopeCastor-chair movement assesses stated floor damage, including joint openingIndustrial-cart load, static parking, threshold impact or universal floor rating
SGS report, p.11One SPC sample: 90 kg, Type W, 25,000 cycles; no visible damage under ISO 4918:2016/Amd 1:2018Other products, 2026 edition, industrial wheel reaction or field route approval
Parterre, pp.12, 15Named dry-back LVT: 24 h traffic / ≥72 h rolling-load restriction; panels for heavy movesEvery floor/adhesive or industrial rolling-load limit
Armstrong FAQ72 h rolling-load caution; ≥1/4 in panels; static and impact loads differSpecific joint geometry or universal product limits
XL Brands/Bostik, 2019Moisture, softened adhesive and weak floor-prep layers can contribute to wheel marks/indentationsUniversal substrate-moisture threshold or caster load limit
Darcor, §IV.CLarger diameter helps negotiate cracks, seams, expansion joints, grates and thresholdsQuantified step/gap limits or floor-damage qualification

Sources and exact evidence locations

  • ISO, ISO 4918:2026, Edition 3, published 2026-11-20, official Abstract/Scope. Official standard page.
  • SGS-CSTC, Test Report SHIN2312002151CM01_EN, 2023-12-29: printed p.1 sample/report limitation; p.11 §7 “Effect of Castor Chair” (90 kg, Type W, Φ750 mm × 5 mm, 25,000 cycles); p.13 §9 “Openings and Height Differences between Floor Panels”. SGS report PDF.
  • Parterre, Commercial Dry Back Luxury Flooring Installation Instructions, 2023-01-12: printed p.12 (24 h no traffic / ≥72 h no rolling loads); p.15 heavy appliances/equipment and floor-protection devices. Installation guide PDF.
  • Armstrong Flooring Commercial, “Performance Criteria FAQs”, “What types of loads affect resilient flooring?” and “How can you determine the durability of resilient floors?”, accessed 2026-11-25. Armstrong FAQ.
  • XL Brands/Bostik, Technical Bulletin: Vinyl Flooring Indentations, revision 2019-04-10, paragraphs 1–5. Technical bulletin PDF.
  • Darcor / Conveyer & Caster, The Ergonomics of Manual Material Handling: Pushing and Pulling Tasks, §IV.C, printed p.19; publication date not stated, accessed 2026-11-25. White paper PDF.

What remains unproven

No source provides a universal industrial floor-joint gap/height limit, a common cross-brand test combining actual caster load with floor construction and joint geometry, or a conversion from ISO 4918 chair cycles to industrial-cart service life. The SGS report is one customer-submitted SPC sample under the 2016 amendment; the exact ISO 2026 test configuration is not reproduced in the public abstract. Parterre and Armstrong instructions must be applied to the actual floor product/adhesive; XL Brands' examples do not supply universal moisture limits. Darcor's larger-wheel advice is qualitative. This supplier has not conducted caster/floor impact, rolling-load, adhesive-cure or joint-crossing tests and makes no such performance guarantee.

New buyer capability: reject “passed chair-castor test = approved for heavy industrial cart”; distinguish permanent floor capability from the temporary adhesive-cure window; identify substrate/adhesive failure risks; and require route-specific joint/threshold evidence before approving a caster substitution.

Return to wheel material comparison · Browse the research library