Product Catalog
Total-Lock Medical Casters — Quiet Swivel Casters for Care Beds and Hospital Equipment
Third-party brand — supplied via our sourcing network
Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term.
Updated 2026-11
Total-lock medical casters are the quiet, light-duty swivel casters specified for care beds, hospital furniture, catering carts and other institutional equipment — casters whose brake must do what a hospital environment asks of it: one pedal that locks both the wheel rotation and the swivel, so a bed occupied by a patient cannot creep or swing while it stands.
The referenced TENTE Agila range contains several distinct caster variants; tread, bearing, fitting and brake options are not interchangeable across every model. Three exact Agila swivel total-lock examples are documented below: 2477PJO075P40 (2.95 in), 2477PJO100P50 (3.94 in) and 2477PJO125P50 (4.92 in). Their published dynamic ratings are model-specific and apply at speeds up to 1.86 mph; the corresponding static ratings are listed separately. These are TENTE manufacturer references, not RollMaster ratings. Confirm the complete MPN and exact tread, bearing, fitting and brake configuration on the current manufacturer quotation.
Specifications
| Type | Swivel caster with total-lock option, plate mount |
|---|---|
| TENTE Agila total-lock exact model references (manufacturer data) | 2477PJO075P40: 2.95 in wheel, 3.94 in overall height, 165.35 lb dynamic / 330.69 lb static; 2477PJO100P50: 3.94 in wheel, 5.31 in overall height, 176.37 lb dynamic / 352.74 lb static; 2477PJO125P50: 4.92 in wheel, 6.30 in overall height, 220.46 lb dynamic / 440.92 lb static. All three are TENTE Agila swivel total-lock model references, rated at up to 1.86 mph; values apply only to the exact MPN/configuration and are not RollMaster ratings. Confirm the current model and tread/bearing/fitting configuration before ordering. |
| Wheel diameters | 2.95 in / 3.94 in / 4.92 in |
| Dynamic load (TENTE exact-model references) | 165.35 lb (2477PJO075P40) / 176.37 lb (2477PJO100P50) / 220.46 lb (2477PJO125P50), at up to 1.86 mph; do not detach values from their exact MPNs |
| Speed rating | Up to 1.86 mph (walking-pace duty) |
| Housing | Steel sheet, medium grade, double-ball raceway |
| Tread / wheel materials | Solid rubber; polypropylene (PP); thermoplastic rubber (TPR) |
| Tread options | Non-marking; electric-conductive |
| Third-party brand — supplied via our sourcing network | Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term. |
| Third-party brand — supplied via our sourcing network | Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term. |
| RollMaster commercial coverage | 18 months as RollMaster commercial coverage; exact coverage, exclusions and order terms are confirmed in the written quotation. Any manufacturer warranty is separate and must be confirmed for the named manufacturer and exact model. |
The three load pairs are TENTE-published values for the exact Agila total-lock MPNs shown in the model matrix (metric-imperial converted), not a family-wide rating or RollMaster commitment. Dynamic and static capacities are different duty values; do not substitute one for the other. Confirm the current MPN, tread, bearing, fitting, brake and operating conditions on the manufacturer quotation.
Applications & Selection
What the medical environment asks of a caster
Hospital and care equipment rolls indoors, loaded with patients or meals, all day, over smooth floors, past people who are trying to rest. That environment sets four requirements at once: quiet rolling (a rattling catering cart is a noise complaint on every corridor), non-marking treads (vinyl and linoleum show every black streak), light effort (nurses steer beds one-handed), and a brake that makes the equipment positively stationary — not just "harder to push."
The total lock answers the last requirement. On a care bed, a brake that stops only the wheel leaves the swivel free, and a free swivel under a patient\'s weight lets the bed\'s casters twist out of line and drift. A total-lock pedal clamps wheel and swivel together, so a braked bed holds its heading as well as its position — which is why total lock is the specification of choice for beds and any equipment that stands occupied.
The electric-conductive tread option exists for a quieter reason: in rooms with sensitive electronics, a caster that bleeds static charge through its tread prevents the small shocks and discharge events that ordinary treads accumulate. Where the facility specifies ESD control, the conductive tread replaces the standard non-marking option — the two options trade against each other, so state which one your environment needs.
Selection points to settle before you RFQ
Start with the equipment maker’s approved load case, not an assumed equal split. Record occupied or loaded weight, centre of gravity, mounting geometry, caster positions, floor transitions and operating speed; use only the number of casters the equipment design and load analysis confirm will share the load. Do not automatically divide by four, and do not assume a larger wheel diameter alone resolves an overload. Select the exact caster MPN against its dynamic rating for movement and static rating for parked duty, then confirm tread, bearing, fitting and brake configuration with TENTE and the equipment manufacturer.
Choose the tread by floor and by electronics. Solid rubber and TPR roll quietly and non-marking on vinyl and linoleum; polypropylene is the economy, easy-cleaning option where floors are hard and loads are light. Electric-conductive treads are a specification, not an upgrade — order them where the facility\'s ESD plan calls for them.
Confirm the brake by function: total lock (wheel + swivel) for beds and occupied equipment; a wheel brake may suffice for static carts that never steer under load. Our guide on how many braked casters a medical cart needs covers the two-of-four versus four-of-four decision.
Quality & Verification
The spec values for Total-Lock Medical Casters draw on 8 field-level source records — 1 tenant confirmed, 4 manufacturer reference, 3 industry reference.
| Claim on this page | How a buyer verifies it |
|---|---|
| Load rating | Catalog ratings bind one configuration. State wheel, bearing, speed and duty. Require that exact rating on the quotation. |
| Sample or test report | Request test data or certificates per SKU. Agree acceptance in writing before the order. |
| Materials and tread | Confirm material by certificate, not description. Unresolved options are fixed at quotation. |
| Bearings | Name the bearing type in the RFQ. "Standard bearing" is not a specification. |
| Standards and compliance | Name the standard and certify against it. An unnamed equivalent is not a certification. |
What this page cannot verify
- No figure on this page is our own lab result.
- The binding rating is the quotation figure.
Sources for this page
- [1] medical total-lock published band (most medical/commercial total-lock casters 250-750 lb per caster; heavy-duty standard up to 1,500 lb, industrial-series to 2,500 lb) — industry reference (https://casterhq.com/blogs/caster-university/double-locking-casters-guide) — accessed 2026-10-28; rendered as published class band next to the tente manufacturer line data, never as supplier ratings
- [2] total-lock definition and medical requirement context (one pedal immobilizes wheel + swivel; the lock most safety standards require for medical and scaffolding) — industry reference (https://www.infordcaster.com/locking-caster-wheels/) — accessed 2026-10-28; independent second publisher for the lock-class definition
- [3] TENTE Agila 2477PJO075P40 exact-model load and dimensions — manufacturer reference (https://media.tente.com/en-us/pdf/77/1/2477PJO075P40_EN.pdf) — manufacturer product sheet: 75 kg dynamic at 3 km/h / 150 kg static; 75 mm wheel / 100 mm overall height; third-party manufacturer model only, not RollMaster rating
- [4] TENTE Agila 2477PJO100P50 exact-model load and dimensions — manufacturer reference (https://media.tente.com/en-cn/pdf/82/0/2477PJO100P50_EN.pdf) — manufacturer product sheet: 80 kg dynamic at 3 km/h / 160 kg static; 100 mm wheel / 135 mm overall height; third-party manufacturer model only, not RollMaster rating
- [5] TENTE Agila 2477PJO125P50 exact-model load and dimensions — manufacturer reference (https://www.tente.com/media/cc/90/37/1773924197/TI_990006130_2477PJO125P50_zh_CN.pdf?ts=1773924197) — manufacturer product sheet: 100 kg dynamic at 3 km/h / 200 kg static; 125 mm wheel / 160 mm overall height; third-party manufacturer model only, not RollMaster rating
- [6] materials (steel sheet housing, double-ball raceway) — manufacturer reference (https://www.tente.com/en-us/industry/healthcare/medical-institutions)
- [7] tread options (rubber / PP / TPR, non-marking, conductive) — industry reference — mappcaster.com line listing via pack collection
- [8] lead_time/moq/warranty — tenant confirmed (first-party) — owner answers 2026-10-26 (Foundation runtime/owner-answers-20261026.json)
Frequently Asked Questions
What does a total-lock brake do that a normal caster brake does not?
A normal brake stops the wheel from rotating; a total lock stops the wheel and the swivel. On medical equipment the difference is practical: an occupied care bed on wheel-braked casters can still swivel and drift its steering out of line, while total-locked casters hold both position and heading. For beds, gurneys and any equipment a patient leans on, total lock is the specified brake.
Which wheel size and load rating should I choose?
Start with the equipment manufacturer’s approved load case and actual load distribution. Do not assume four casters share equally: verify the centre of gravity, mounting geometry, caster positions, floor transitions and operating speed, then calculate the load on each effective support. Match that load to the dynamic rating for movement and the static rating for parked duty of the exact TENTE MPN. A larger diameter is not an automatic remedy for overload; confirm the complete tread, bearing, fitting and brake configuration with the manufacturer before ordering.
What should my medical caster RFQ include?
Load per caster (with the equipment\'s occupied/loaded weight), wheel diameter and tread choice (solid rubber, PP, or TPR; non-marking or electric-conductive), brake type — state total lock explicitly — mounting plate or stem dimensions, floor type, hygiene or cleaning chemicals involved, and quantity. Mention the destination facility type: hospital, care home and catering duty quote slightly different tread and bearing defaults.
Ordering & Documentation
Documents
Orders ship with a packing list and commercial invoice. On request we provide the caster\'s dimension sheet (plate size, bolt pattern, wheel diameter, overall height) and a tread/material statement for the quoted configuration, so your equipment drawings can be checked before production.
Quotation
A quotation needs: load per caster, wheel diameter, tread (including non-marking or electric-conductive specification), brake type (total lock), mounting dimensions and quantity. The per-size rating confirmed on the quotation — not the published line values — is the order commitment.
Sample & supply
Third-party brand — supplied via our sourcing network. Product references on this page may come from more than one third-party source. A retailer or catalog is not necessarily the manufacturer. Where the original manufacturer or exact model/part number is not identified, it is not verified by this listing; confirm both in the written quotation. Any lead time, MOQ or warranty shown as our offer is a RollMaster quotation term, not a third-party manufacturer's published term.
Storage & shipping
Medical casters are light and ship cartoned. Store them in their packaging away from direct sunlight — rubber and TPR treads age under UV — and keep brake pedals free of packing debris. Before installation, cycle each total-lock pedal a few times; a pedal that sat compressed in a carton should move freely before the equipment enters service.